Phd2 Oag Settings

Color OSC cameras see even less stars. Alles zo goedkoop mogelijk haha. The screenshot has the guiding graph and target. Portions of this text are lifted directly and without shame (but with permission) from notes created by Neil Heacock. Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given conditions. the StarShoot G3 DSCI is compatible with Win 10 and uses ASCOM to interface with PHD2. To view the blog post by NIDA Director Dr. To view videos by the NIDA co-authors, go to: Dr. Rao, Huiying; Jiang, Dong; Wang, Jianghua; Xie, Xingwang; Wei, Lai. 25 SCT Lessons learned from my first use of Celestron's off-axis guider and how to center on a guide star indoors and during the day!. 6mm, 6016x4016 3. My telescope has FL of 731 mm f 4. He sent me his settings: RA Aggressiveness: 60 RA Hysteresis: 10 Max Dec Duration: 75 Min Motion: 0. Mechanism of Cardioprotection by Early Ischemic Preconditioning Article · Literature Review in Cardiovascular Drugs and Therapy 24(3):225-34 · June 2010 with 27 Reads How we measure 'reads'. OAG and Ultrastar autoguider, Optec Handy Stepper Motor focuser. The Atik Infinity is supplied with our custom software dedicated to video astronomy, with a Sony ICX825 sensor embedded with EXview HAD CCD II™ technology has a generous 6,45 µm pixel size. I bought a 814a from OPT here in the US. Currently, there is no effective vaccine to prevent hepatitis C virus (HCV) infection, partly due to our insufficient understanding of the virus glycoprotein immunology. I am also new to PHD2, and am using all the default settings. Using PHD2 Guiding There are five basic steps to start guiding. 17 figure was for 1x1 binning on the lodestar, goes down to 0. The ability to ‘bin’ the CCD means the QSI-6162 is suitable for focal lengths right up to 2. een gelijmde logitech C270 webcam. Thickness is about 12-13mm total for the OAG and its adapters. Fed-Police Vigilantes Persecute Citizen Targets * ETK Introduction: This series of articles and posts, compiled between 2010 and 2012 by Geeldon, may be the single most informative and important post on this website. I am pretty new using PI, but reaching out for a little help to see if this can be resolved in processing. the entire night UPDATE: My PHD2 settings for the focal length of my guide scope were wrong - so my guiding results aren't as good as PHD2 was indicating. It’s certainly true that the default settings in PHD2 are focused on the types of mounts most users have, so it wouldn’t be too surprising for those were sub-optimal for a Paramount. Settings for sidereal, lunar and solar tracking rates, slew rates, anti-backlash settings for either axis, Asicap ST4 autoguiding. Click the above to download the core software. But it does show up noise well, including hot pixels. Correspondence between OAG & OGD's relating to Confidence and Supply Agreement MS Word Document , 52. My computer is an iMac. Meade Instruments: A world leader in the manufacturing of Telescopes, Solar Telescopes, Microscopes, Optics, Binoculars, for amateur astronomers and hobbyists. – You can let PHD2 auto-select the star (s) – Adjust the gamma-slider to see all the stars – Don’t pick a bright, saturated star – Increase the guide exposure if necessary – Use the star-profile tool to confirm focus and shape – you want a pointed top. There is some backlash in both the RA and Dec axes. Last night I found that turning on the PHD2 'RA only' flag in the Advanced settings, Global tab really helped my DEC guiding. Driver support: PHD2, AltairCapture, SharpCapAltairCapture OS support: Win XP 32bit / Vista / 7/8/10 (32 & 64 bit) NOTE: Windows 10 is recommended for best USB performance, with 2013 or later USB host controller v1. I have 25x300s subs with Darks, Flats and Bias(superbias too) on IC1805 from Friday. Unlike the old version, PHD2 will figure this out for you. Re: PHD2 and EQ6 - RA calibration failed star did not move enough ^^^ Not sure if my logic is correct but next to the connect button is the settings button for the mount. Applications checks position of a star on an image from a guide camera, and if it detects any shift in the position of the star - it sends corrections to the mount. That's an important point, well worth sharing. I am using a Lakeside motorfocuser on a WO Star 71 with a QSI 683-WSG. Astro-images taken through a telescope on a tracking mount provide breathtaking color and detail that you just can't see with your eyes alone. How to setup Autoguiding in PHD2 This tutorial goes over how to setup autoguiding in PHD2 and also offers a couple tips and tricks to help get the most out of your Fitting Atik OAG to EFW3 and setting up for use with Lodestar X2 Atik off axis guider and Baader eyepiece holder are available from First Light Optics via the links below:. Guidescope is een simpele oude 8x50 zoeker, icm. I was pixel peeping too when I first started using guiding but always ended up messing with PHD2 settings too much and ended with bad stars even at 480mm now I image at 800mm with 10 minute exposures with perfect stars and the only thing that changed is by ignoring most of the settings in PHD2 and change only what is necessary on a night with excellent seeing and then forget it. Ascom i62 a premium VoWiFi handset that is easy to carry, robust and drop resistant. explain many of the functions and settings of PHD, especially for the beginner. phd2 guider settings #27138 If you want to use PHD2 for guiding with Ekos, you can choose to have the camera connected to KStars and use it with INDI, or you can connect the guide camera directly to PHD2 if you prefer. Therefore, should I. In the PHD2 program, the guide camera works best if you capture a dark-frame set using PHD2's dark library wizard feature. Diagnosing Trailed Stars. Mechanism of Cardioprotection by Early Ischemic Preconditioning Article · Literature Review in Cardiovascular Drugs and Therapy 24(3):225-34 · June 2010 with 27 Reads How we measure 'reads'. In a subsequent video, I will show you how an off-axis guider will improve PHD2 guiding. Most important setting not shown below is mount guide rate to 1. 2″ big sensor which means you can have a 4 times bigger Fov than 120mm. The drift align tool in PHD2 can be used to quickly obtain a precise polar alignment of your equatorial mount. Guiding: OAG & Lodestar - Starlight Χpress / PHD Guiding Exposure: Ha 15 x 600sec / RGB 6x300sec /channel + darks, bias & flats, @ -10C total exposure 4 hours. Both of these shots are with the 208mm f/3. Polar Alignment is a SharpCap Pro feature. The Israel Society for Neuroscience—ISFN—was founded in 1993 by a group of Israeli leading scientists conducting research in the area of neurobiology. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given First Use of Celestron's OAG on a C9. 09 if you 2x2 bin, their recommended setting, not way to check the binning in PHD if using the SXV driver, well not that I have found anyway, can only set/check binning via the ASCOM driver and that has more settings to confuse the unwary. 晴れたり曇ったりする中球状星団なら薄雲も突き抜けてくれるかという事で撮ってみました。何度撮っても満足な感じにならないです。星の色は難しいです。200RC+CCDT67+Sx miniwheel/OAG(lodestar+PHD2)+Baader CRGB+Sx694 C:1min. I wonder if I am using SGP correctly to autofocus… It works, but it can take quite a while and has occasionally failed me. Had to throw out one sub due to really bright airplane light streaks. 7 focal reducer, ASI533MC imager, OAG using ASI120mini, PHD2 and of course APT. ZWO OAG でガイド そしたら、APT がいつのまにか便利(?)になってて、撮影時の Gain を settingsで ASCOMドライバから変更しなくても良くなってるっぽい。 APT で撮影して PHD2 でオートガイドのテスト。PHD2 は QHY5L-II-C を使った 240mm。. phd2 guider settings #27138 If you want to use PHD2 for guiding with Ekos, you can choose to have the camera connected to KStars and use it with INDI, or you can connect the guide camera directly to PHD2 if you prefer. I would like to use PHD2 for guiding, using. Off Axis Guider Tutorial Tutorials Jason Matter April 30, 2020 OAG , Off Axis Guider , Starlight Xpress , OAG Tutorial , Off axis guider tutorial Comment I get asked a lot about whether its better to use a guide scope vs an Off Axis Guider or OAG and I really think its depends on your gear. 6mm, 6016x4016 3. Any help would be greatly appreciated! thanks! Steve. PHD2 is a telescope autoguiding software that automates the process of tracking a guide star. Jeong, Yun-Jeong; Cho, Hyun-Ji; Magae, Junji. You have a lot of equipment and sometimes it is difficult to get it all working together. So, I changed the settings to "Hysteresis" in the hopes of better Dec corrections. Open this and check the 'Activate stretch display' check box. Welcome to the Moravian Instruments web site devoted to cameras for low light imaging in astronomy and microscopy. een gelijmde logitech C270 webcam. In this study, we investigated the potential molecular mechanisms. The QSI-6162 model camera model employs a KAF-16200, 16 megapixel, full frame CCD image sensor with microlens technology that has been specifically produced for astrophotography. Much less weight on the mount as there is no second scope. Guiding: Atik OAG, PHD2, QHY5L-II I have tried to image the Andromeda Galaxy before but couldn't quite fit the entire object in the field of view. 80"), Calibration Steps: 200msec, Lowpass2 Dec guiding algorithm, 4 seconds auto guiding exposure and dithering 5 pixels. Click each "Connect" button to test the. Needs a mount with ASCOM control. Total exposure time through LRGB filters is 38 hours. Fed-Police Vigilantes Persecute Citizen Targets * ETK Introduction: This series of articles and posts, compiled between 2010 and 2012 by Geeldon, may be the single most informative and important post on this website. Software: Sgpro, phd2, stellarium, eqmod, and processed in pixinsight. Thats why ASCOM uses HUB technology. The light splitting is achieved by a prism in a device called the Off-Axis-Guider - or OAG for short. " Normal settings rage from about 70% to. SharpCap (a 3rd party application) is also fully supported and tested with native drivers. Although these are called "advanced" settings, they are not particularly difficult to understand, and you shouldn't hesitate to explore them. We recommend using the current core software in all circumstances. Library Assessment in Higher Education Author Joseph R. Off-Axis Guider - User’s manual Thank you for purchasing the Atik Off-Axis Guider (OAG). I am pretty new using PI, but reaching out for a little help to see if this can be resolved in processing. Astro-images taken through. 45, Calibration Steps: 250msec, Auto/Resist Switching, 1 sec guiding exposure. Calibration and Post-processed with PixInsight. I am trying to use an STT-8300M with an 8-Position Filter Wheel that has OAG built-in. With this settings I reach 100% sub utilization at 2 years ago. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. It consists of 18 x 20mins subs. ASI174MM mini is designed for Big FOV guiding. PHD2 is a telescope autoguiding software that automates the process of tracking a guide star. The problem I ran into was when I hit the meridian my mount stopped tracking that's fine, I think I understand how to change limits and could have let go a lot further. The 6-micron pixel size make this camera the ideal imaging partner for a wide range of focal length telescopes. Any help would be greatly appreciated! thanks! Steve. You have a lot of equipment and sometimes it is difficult to get it all working together. 5, setting up a new profile in PHD2 I'm assuming I enter the FL of 731 mm and everything else remains the same since I'm using the same camera and same mount. This is an important aspect of deep sky astrophotography because it allows you to focus on capturing successful long exposure images and get the most out of your telescope mount. (Also my camera program and image I'm shooting). It’s certainly true that the default settings in PHD2 are focused on the types of mounts most users have, so it wouldn’t be too surprising for those were sub-optimal for a Paramount. A wide range of features makes SharpCap suitable for many types of astro-imaging including Planetary, Lunar, Solar, Deep Sky and EAA (Electronically Assisted Astronomy). 25 SCT Lessons learned from my first use of Celestron's off-axis guider and how to center on a guide star indoors and during the day!. PHD2 options For PHD2 you need to set the network name of the computer running PHD2 and the port number. Minimum Settle Time. Currently I manually start an autofocus run before starting my sequence. I think I need a laptop, software, more power, guide scope, CCD imager or dslr, and money, time, guidance (no pun intended) and patience. Settings were 23x20s 1600 raw. I am in a permanent observatory above my garage roof which is about 12 feet above street level. Email Friend { width: 340, height: 340, defaultImage: '', layers: '52064' } Details. The deep-sky images look so exquisite with their masses of detail and perfectly round, pinpoint stars. it is also only compatible with PHD2 v 2. 404 membros. Clicking yes will fire up ASCOM/EQMOD and get the settings for guiding directly from it: For my setup, I hadn't adjusted any settings of EQMOD, it determined the EQ6-R Pro's configuration to be 0. Trying to set up my current HEQ5 Pro for astro with laptop. And basically with OAG you should only use high sensitive mono cameras. I will update. PHD2 Guiding. Any help would be greatly appreciated! thanks! Steve. " Normal settings rage from about 70% to. I cover OAG and 1 year ago. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. You can test your polar alignment accuracy without a SharpCap Pro license to learn how the feature works, but you will need to buy a SharpCap Pro license to use the polar alignment adjustment stage that guides you in to correct alignment. Download File PDF Qhy5 Autoguider Price PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. Alternatively, PHD2, Lodestar Live, AstroArt and MaximDL all support the Ultrastar C and may be OAG', or our 'Slim OAG + Filter Wheel'. This program can be used in conjunction with many atrophotography programs, such as Sequence Generator Pro. 6mm, 6016x4016 3. 2 Lepus focal reducer. Emily Einstein Discusses How Overdose Deaths are Counted. AutoGuider is not recommended for use as a stand-alone imaging camera. It bears a striking similarity to M33, being about 50,000 light years in diameter and containing numerous star-forming H II regions. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. 8x sidereal, so that's what I've been doing. Hypoxia-inducible factor (HIF)-1 plays an important role in tumor progression, angiogenesis and metastasis. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given First Use of Celestron's OAG on a C9. Need help with PHD2 autoguiding? This Star Stuff Video Series episode has some great tips on PHD2 setup and troubleshooting. With the Orion StarShoot AutoGuider, precision autoguiding for deep-sky photography is now easier and more economical than ever. Using an off-axis guider (OAG). Total exposure time through LRGB filters is 38 hours. To view the blog post by NIDA Director Dr. Open this and check the ‘Activate stretch display’ check box. PHD2 is a wonderfully flexible program and is scriptable. Skywatcher 200P with an astro modded Canon 700d, cls ccd filter, field flattener, guided by OAG, ASI 120, PHD2. Thats why ASCOM uses HUB technology. And basically with OAG you should only use high sensitive mono cameras. 25 SCT Lessons learned from my first use of Celestron's off-axis guider and how to center on a guide star indoors and during the day!. Yo solo llevo dos días probando PHD2 pero he visto que al estar conectado a EQMOD el apartado de la declinación sale sombreado y no se puede modificar, así que entiendo que es como dices. ZWO ASI290MM Mini Monochrome Imaging Camera One of ZWO's two initial Mini Cameras, the ASI290 Mini features a Sony IMX290/IMX291 1/3" sensor (5. It’s certainly true that the default settings in PHD2 are focused on the types of mounts most users have, so it wouldn’t be too surprising for those were sub-optimal for a Paramount. The 6-micron pixel size make this camera the ideal imaging partner for a wide range of focal length telescopes. This is an important aspect of deep sky astrophotography because it allows you to focus on capturing successful long exposure images and get the most out of your telescope mount. My idea it to get at least 20 hours worth of data, so expect an enhancement in the next few days. Replied by Daan on topic Connect ZWO Asiair to Avalon Linear (Stargo) problem is solved In the telescope settings there is a pulldown menu in which you can select next to the "Avalon Stargo" mount also the mount "Avalon Legacy". I did get equally good results with the "normal" settings on OAG and improved by about 50% with some mechanical work on my mount but am still getting RMS about the order of 1-2 secs. The camera was his Canon 450D (modified), focused with 8" Bahtinov mask. PHD2 guider. Hi I have an SBIG STT-8300 camera. Color OSC cameras see even less stars. ZWO ASI290MM Mini Monochrome Imaging Camera One of ZWO's two initial Mini Cameras, the ASI290 Mini features a Sony IMX290/IMX291 1/3" sensor (5. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. Of note, I have found the home position for the EXOS-2GT and with good PA, targets are always in frame with the first goto. Unfortunately bushfire smoke looks like wiping me out for months so I haven't been able to test very much (2 nights only since last posting). 3 Coma Corrector on a Celestron Alt-Az Fork with Wedge. If you're using autoguiding software like PHD2, the default settings will usually work, but every mount-scope combination is different. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. 9 Newt + 5DmkII: 30x60sec lights, 10x darks, 10x flats, Using tonight's settings as a starting point: 1). ASI174 mini have 1/1. I will update. Therefore, should I. Recently I installed an off axis guider (OAG) on my Edge 8HD and plan to use my same ZWO camera and PHD2. Meade Instruments: A world leader in the manufacturing of Telescopes, Solar Telescopes, Microscopes, Optics, Binoculars, for amateur astronomers and hobbyists. 8x sidereal, so that's what I've been doing. Software: Sgpro, phd2, stellarium, eqmod, and processed in pixinsight. Currently I manually start an autofocus run before starting my sequence. The OAG can also be supplied on its own, with an extension The settings shown above are generally satisfactory as a starting point, although some will probably need refinement for best results. PHD2 settings: RA Aggressiveness: 60, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. This is the exact reason I turned ‘Timed Finishing’ off in my settings. PHD2 ran reasonable well with default settings, but ran into a couple issues. D3200 Digital SLR with 18-55mm Lens. Astro-images taken through. Click each "Connect" button to test the. And basically with OAG you should only use high sensitive mono cameras. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. 25 Upgrade Focuser to William Optics DDG Crayford Celestron C9. I'm always fighting, without success, with my guiding settings in PHD2. Minimum Settle Time. Ascom i62 a premium VoWiFi handset that is easy to carry, robust and drop resistant. It works with MoonLite's Dual port DRO display controller only. Well, as it turns out, every data point from the whole night is contained in it! Every correction, guide star SNR, RMS error, etc. 45, Calibration Steps: 250msec, Auto/Resist Switching, 1 sec guiding exposure. Hello everybody, I'm taking the step and going OAG. performed for PHD2, HIF-l α, UCHL-1, FASN and SREBP-1c. I guides with PHD2 with a Lodestar autoguider. This guide does not apply to the older Gemini I system or non-Losmandy Mounts Let’s Run Through Some Assumptions 1. PHD is a free and popular application for mount guiding. In this video I discuss Auto Guider options. Captured and automated with SGP. I am guiding with a 60mm APM Deluxe guide-scope which is 284 Focal length. Pros: Relatively cheap to purchase. The Atik Infinity is supplied with our custom software dedicated to video astronomy, with a Sony ICX825 sensor embedded with EXview HAD CCD II™ technology has a generous 6,45 µm pixel size. Trying to set up my current HEQ5 Pro for astro with laptop. 25 Upgrade Focuser to William Optics DDG Crayford. Different focal lengths, in particular, will require different autoguider settings based on the focal length and often the seeing. I would like to use PHD2 for guiding, using the 8300 guider. Another issue is field curvature / coma. I did get equally good results with the "normal" settings on OAG and improved by about 50% with some mechanical work on my mount but am still getting RMS about the order of 1-2 secs. I have 25x300s subs with Darks, Flats and Bias(superbias too) on IC1805 from Friday. Use with Off-Axis Guiders: click File -> Connection Settings. ZWO is the company who makes the ASI294 and the ASI120. Antes se ponía a mano, pero ahora PHD2 hace como MaximDL, al estar conectado a la montura sabe a donde apunta y no es necesario recalibrar. This "guide to guiding" was created to fill that void. Hi Folks, I just bought the new Celestron CPC 9. ASI174MM mini is designed for Big FOV guiding. Email Friend { width: 340, height: 340, defaultImage: '', layers: '52064' } Details. that I have not worked with. 0 Megapixel IMX178 STARVIS Exmor R back-illuminated CMOS sensor. The process takes a little bit of practice, but after doing it a few times, you should be able to obtain an accurate polar alignment in minutes. You have a lot of equipment and sometimes it is difficult to get it all working together. Product SKU: 52064. We all do it—ogle over the astrophotographs taken by the masters. Orion StarShoot AutoGuider. Fl is dacht ik 180mm. We recommend using the current core software in all circumstances. Need help with PHD2 autoguiding? This Star Stuff Video Series episode has some great tips on PHD2 setup and troubleshooting. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. The settings you gave, give me something to consider. There is debate here, once i have it up with the dome, i might consider laying plywood ontop of the 5/4 to seal off from critters and then use the interlocking foam mats everyone uses for flooring, along with rubber padding along the edges of the dome, as well as caulking on the outside of the dome (the 27th is a spare). PHD2 settings: RA Aggressiveness: 60, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. Guiding through ZWO OAG I have attached the guide log. So here it is, click on the image for a larger. Guiding: OAG & Lodestar - Starlight Χpress / PHD Guiding Exposure: Ha 15 x 600sec / RGB 6x300sec /channel + darks, bias & flats, @ -10C total exposure 4 hours. GLA supplementation regulates PHD2 mediated hypoxia and mitochondrial. Unlike the old version, PHD2 will figure this out for you. The reason for this is to decrease the chance of the mount overshooting the star, going back the other way on the next guide command, and overshooting in that direction too, “ping-ponging. Wanneer je naar een ander object gaat moet je opnieuw calibreren. This is a work-in-progress and so far represents data captured over 2 nights, 2019. This method involves stacking many short exposures to achieve a high sensitivity with simple equipment. You get a Aug 12, 2017 · BEST Video Settings To Record Video On ANY Nikon DSLR (D5200/D5300/D5500 FULL Tutorial) - Duration: 16:05. Care is needed to make sure the prism on the OAG is not too low as it will show up in any image captures. 25 Upgrade Focuser to William Optics DDG Crayford. Re: A new OAG with PHD2 and ZWO ASI120MC - questions Between the camera and the reducer - the Celestron EdgeHD t-adapter and the Orion thin OAG with its Canon t-ring and t-thread adapter. Product SKU: 52064. NGC 2403 (also Caldwell 7) is an intermediate spiral galaxy in the constellation Camelopardalis. In PHD2 I am able to identify the Meade Classic and Autostar I (ASCOM) mount setting. ZWO ASI Cameras tem 7. It bears a striking similarity to M33, being about 50,000 light years in diameter and containing numerous star-forming H II regions. settings and open the 'View' menu. Guiding: TSOAG9 Off-Axis-Guider, Starlight Xpress Lodestar X2, PHD2 Camera: Nikon D5300 (unmodified) (sensor 23. I use CCDSOFT, but the settings are 50% aggressiveness , 0. I was pixel peeping too when I first started using guiding but always ended up messing with PHD2 settings too much and ended with bad stars even at 480mm now I image at 800mm with 10 minute exposures with perfect stars and the only thing that changed is by ignoring most of the settings in PHD2 and change only what is necessary on a night with excellent seeing and then forget it. OAG with PHD2 Bruce Donzanti #69831. You still get field rotation regardless. 45, Calibration Steps: 250msec, Auto/Resist Switching, 1 sec guiding exposure. PHD2 settings: RA Aggressiveness: 60, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. 5 Tips for Better PHD2 Guiding. Now to get something that looks similar to Andy's picture below, I will be well on my way. It can perform many complex tasks in order to meet your imaging needs. Wanneer je naar een ander object gaat moet je opnieuw calibreren. For full size images, I would like to continue to use The Sky X Pro controllong the main STT camera. 3 I will be using phd2 and using APT to capture subs etc this also has dithering built in (in the global tab ditheri. PHD2 Guiding. I wonder if I am using SGP correctly to autofocus… It works, but it can take quite a while and has occasionally failed me. Die Idee, dass man die Guiding-Kamera (am OAG) ausgerichtet auf die Achsen montiert, wäre die, dass so das Pol-Align in PHD2 auch ohne vorherige Kalibrierung funktioniert. Similarly, if you're guidng with an OAG on your main imaging scope, the focal length will be that of the main scope. it is also only compatible with PHD2 v 2. l have had some success with PHD2 using the asi290mm and oag. Fl is dacht ik 180mm. You still get field rotation regardless. In this you will see an option called ‘Max palette stretch’. How to setup Autoguiding in PHD2 This tutorial goes over how to setup autoguiding in PHD2 and also offers a couple tips and tricks to help get the most out of your Fitting Atik OAG to EFW3 and setting up for use with Lodestar X2 Atik off axis guider and Baader eyepiece holder are available from First Light Optics via the links below:. Don't worry, I'm not going to dig in to how the light moves through the prism etc. Antibodies Targeting Novel Neutralizing Epitopes of Hepatitis C Virus Glycoprotein Preclude Genotype 2 Virus Infection. There is some backlash in both the RA and Dec axes. The Low limit for the white was set just above the noise level and the High limit for the Shadows was set just above this noise level as well ~0. 3 Coma Corrector on a Celestron Alt-Az Fork with Wedge. I am about to start some AP this year and am researching what'd be best to start with myself. Much less weight on the mount as there is no second scope. Advanced settings are accessed by clicking on the 'Brain button' in the main display. 5 Tips for Better PHD2 Guiding. 7k ohm and it ran but would periodically restart every 10-20 seconds (4. If you can dredge up some data and are willing to work through some testing, we should be able to nail this down. Sequence Generator Pro is an extremely powerful image capture suite. The M55 globular cluster (5x 240s and 6x 300s + darks, guided with an OAG) is taken with this new setup, with little polar alignment. The ability to ‘bin’ the CCD means the QSI-6162 is suitable for focal lengths right up to 2. 6 arcsec RMS. Unfortunately bushfire smoke looks like wiping me out for months so I haven't been able to test very much (2 nights only since last posting). Thanks for the comments on PHD2, by the way. it? I compare PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given How to Setup PHD2 (Autoguide Software) I've received a lot of requests Planning and OAG Setup I go through the process of saving the ED102 imaging profile in APT before. Total exposure time through LRGB filters is 38 hours. Pros: Relatively cheap to purchase. How to setup Autoguiding in PHD2 This tutorial goes over how to setup autoguiding in PHD2 and also offers a couple tips and tricks to help get the most out of your Fitting Atik OAG to EFW3 and setting up for use with Lodestar X2 Atik off axis guider and Baader eyepiece holder are available from First Light Optics via the links below:. Help with PHD and Off axis guider settings. I would like to use PHD2 for guiding, using. big SCTs) to avoid flexure issues. Captured and automated with SGP. Using an off-axis guider (OAG). Australian Amateur Astrophotography has 5,209 members. How to Setup PHD2 (Autoguide Software) I've received a lot of requests from people that have asked if I could show what my settings are in the PHD2 auto-guiding software. SciTech Connect. Despite its compact dimensions and fairly modest price, it has a modern sensor and produces great photographs - find out if it's right for you in our full review. OAG or separate guide 'scope? Separate guide scope with a QHY II L Mono. I am pretty new using PI, but reaching out for a little help to see if this can be resolved in processing. He sent me his settings: RA Aggressiveness: 60 RA Hysteresis: 10 Max Dec Duration: 75 Min Motion: 0. So here it is, click on the image for a larger. PHD2 ran reasonable well with default settings, but ran into a couple issues. For now, it appears that the Starlight Xpress SXV-AO-LF together with PHD2 is the only solution to address the differential-flexure issue with a second imaging camera. Borte 3 mountain top, sky bright 21. I have 25x300s subs with Darks, Flats and Bias(superbias too) on IC1805 from Friday. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. Agena Astro was out of stock on this item at the time but I was able to find one at Adorama for the same price. What I find myself doing lately is. ASI174 mini have 1/1. The PHD2 settings dialog looks like this (note that you can set this for the current sequence via the control panel or you can set this per equipment profile via the equipment profile manager): The install path (described above) is a global setting and applies to all sequences and profiles. This is an important aspect of deep sky astrophotography because it allows you to focus on capturing successful long exposure images and get the most out of your telescope mount. How Does it Work. The image from the guide camera is then analysed by a piece of software called PHD2. But I'm frustrated by the polar alignment. I am using a Lakeside motorfocuser on a WO Star 71 with a QSI 683-WSG. The only way to reduce PAE is through more accurate alignment methods like classic drift alignment or PHD2 assisted drift alignment. My telescope has FL of 731 mm f 4. If you really can't determine what the guide speed settings are in the mount, leave the setting at the default value of 0. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. Well, as it turns out, every data point from the whole night is contained in it! Every correction, guide star SNR, RMS error, etc. x66 RGB:1min. An OAG is an adapter that fits on the back of your actual scope (not a separate scope) and has a tiny little pick-off mirror. Hopefully in the very near future i will have a crack at guiding,set tup is as follows sw200p on a EQ6 mount canon 1000D qhy5L-11 guide camera using a qhy guide camera F/L 130mm f4. In short, SGPro can be as powerful as you want it to be. I guides with PHD2 with a Lodestar autoguider. That way I am in focus, start the sequence and the first target is centred, PHD2 starts guiding and. Couldn't get it to work properly and most of the time the cause of failure is on my PHD2 AutoGuiding, not because of the software, but because of the OAG. Guiding with phd2. 5 cant keep up. Orion StarShoot AutoGuider. AutoGuider is not recommended for use as a stand-alone imaging camera. Thugocracy: U. I wonder if I am using SGP correctly to autofocus… It works, but it can take quite a while and has occasionally failed me. 09 if you 2x2 bin, their recommended setting, not way to check the binning in PHD if using the SXV driver, well not that I have found anyway, can only set/check binning via the ASCOM driver and that has more settings to confuse the unwary. PHD2 options For PHD2 you need to set the network name of the computer running PHD2 and the port number. Astrodon Green filter, 16 x 7 minutes, 1x1. it is also only compatible with PHD2 v 2. Off Axis Guiding is explained, using the ZWO OAG, an RC6, a DSLR and a Setting Up An Off-Axis Guider We look at the idea behind the OAG, its challenges, and its benefits and show how Stellarium can be used to identify potential PHD2 Grundlagen In diesem Video beschreibe ich euch grundlegend die Software. A wide range of features makes SharpCap suitable for many types of astro-imaging including Planetary, Lunar, Solar, Deep Sky and EAA (Electronically Assisted Astronomy). Struggles with OAG, and SGP. (Also my camera program and image I'm shooting). He used his Skywatcher Explorer C8 200 with a F6. PHD2 has a large set of parameters that can be adjusted to optimize your guiding performance. MoonLite Dual Focuser V2. 5, setting up a new profile in PHD2 I'm assuming I enter the FL of 731 mm and everything else remains the same since I'm using the same camera and same mount. I am about to start some AP this year and am researching what'd be best to start with myself. OAG's are usually used for very long focal length scopes (e. All data is captured in Hydrogen Alpha & consists of: 16 x 480s 79 x 90s just over 4 hours total. Borte 3 mountain top, sky bright 21. In short, SGPro can be as powerful as you want it to be. QSI WSG + PHD Guiding Help Needed. But I'm frustrated by the polar alignment. 6mm, 6016x4016 3. The ability to 'bin' the CCD means the QSI-6162 is suitable for focal lengths right up to 2. 5KB This file may not be suitable for users of assistive technology. I was poking around through the PHD2 software settings and decided to see what all the log file had in it that might be useful. Eine anschließende Kalibrierung in PHD2 wiederum ist gescheitert (Orthogonalitätsfehler), eben weil das Pol-Alignment so schlecht war. Now I was attempting to use the OAG ZWO ASI 178, and I had all kinds of trouble. I am using a Canon 600d (modded) with a Lacerta OAG. PHD2 is my guide software. Nora Volkow, go to: The True, Deadly Scope of America’s Fentanyl Problem. Care is needed to make sure the prism on the OAG is not too low as it will show up in any image captures. OAG and Ultrastar. ASI174 mini have 1/1. Reduces problems with flexure and mirror shift. But it does show up noise well, including hot pixels. I was never able to get an image to appear, no matter what settings I used. May 23, Couldn't get it to work properly and most of the time the cause of failure is on my PHD2 AutoGuiding, not because of the software, but because of the OAG. Meade Instruments: A world leader in the manufacturing of Telescopes, Solar Telescopes, Microscopes, Optics, Binoculars, for amateur astronomers and hobbyists. Applications checks position of a star on an image from a guide camera, and if it detects any shift in the position of the star - it sends corrections to the mount. Driver support: PHD2, AltairCapture, SharpCapAltairCapture OS support: Win XP 32bit / Vista / 7/8/10 (32 & 64 bit) NOTE: Windows 10 is recommended for best USB performance, with 2013 or later USB host controller v1. Currently I manually start an autofocus run before starting my sequence. Maybe go back to using guide scope using original PHD2 guide scope settings once more to make sure that everything is working again and then revert back to OAG and change two important PHD2 settings: Search Region (50 pixels) and Minimum Move (1. Click the above to download the core software. With its small 2. Calibration (including Dark Subtraction) and Post-processed with PixInsight. Captured and automated with SGP. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. Unfortunately bushfire smoke looks like wiping me out for months so I haven't been able to test very much (2 nights only since last posting). Unlike the old version, PHD2 will figure this out for you. These are the current settings that I use in PHD2 and EQMOD. This is a work-in-progress and so far represents data captured over 2 nights, 2019. 5, setting up a new profile in PHD2 I'm assuming I enter the FL of 731 mm and everything else remains the same since I'm using the same camera and same mount. The ability to 'bin' the CCD means the QSI-6162 is suitable for focal lengths right up to 2. I know plenty of tuts and advice out there, but most for various guide scopes with a g. This software is setup. QSI WSG + PHD Guiding Help Needed. First, it warned me I should disable Synchronous Pulseguide in the driver, I couldn’t find that setting and not sure I want to disable even if I could!. Introducing a New Way to Auto-Focus. It’s certainly true that the default settings in PHD2 are focused on the types of mounts most users have, so it wouldn’t be too surprising for those were sub-optimal for a Paramount. The reason for this is to decrease the chance of the mount overshooting the star, going back the other way on the next guide command, and overshooting in that direction too, “ping-ponging. This tutorial will help you get PHD2 setup and running with the default settings. My computer is an iMac. 5 there were a lot of good changes in the versions between 2. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given First Use of Celestron's OAG on a C9. 25 SCT Lessons learned from my first use of Celestron's off-axis guider and how to center on a guide star indoors and during the day!. All data is captured in Hydrogen Alpha & consists of: 16 x 480s 79 x 90s just over 4 hours total. You have a lot of equipment and sometimes it is difficult to get it all working together. Calibration (including Dark Subtraction) and Post-processed with PixInsight. As it stands now, PHD2 talks to FocusLock and the Camera Sync program TheSkyX, and runs the SXV-AO-LF very reliably. I was poking around through the PHD2 software settings and decided to see what all the log file had in it that might be useful. 2x8x12″ framing board and joists x 14 (so 10 for joists/boxing in the pier area) 4x4x8 x 4 for posts (which ill dig down 2 feet which should be good enough, yes 4 foot is the frost line but our bigger pool deck only went down about 3 feet with 4 foot high posts and its been solid; i plan on wedging the posts in the hole temporarily and putting on the 2×8 board making it level and then. I have been using PHD2 for a few months on a refractor. (Also my camera program and image I'm shooting). PHD is a free and popular application for mount guiding. x66 RGB:1min. SciTech Connect. A guidescope attaches to the main telescope via mounting rings that allow it to be aimed independently to some. Off-Axis Guider or OAG. Deconvolution: I create a luminance clone of the image and use the STF settings with Histogram Transformation to stretch it. The Atik Infinity is the first Atik CCD camera dedicated to video astronomy. Guiding was PHD2 + TS Optics 9mm OAG + GPCAM1030M MOUNT : EQ6-R + Bluetooth and EQMOD IC1848 Soul Nebula - ASI1600MM Pro 200gain 22offest 224 minutes (Ha 40 x 120s Oiii 36 x 120s Sii 36 x 120s) by Nick Davis , on Flickr. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given First Use of Celestron's OAG on a C9. But I'm frustrated by the polar alignment. I cover OAG and 1 year ago. Some features may be different for other versions. Need help with PHD2 autoguiding? This Star Stuff Video Series episode has some great tips on PHD2 setup and troubleshooting. This program can be used in conjunction with many atrophotography programs, such as Sequence Generator Pro. But it does show up noise well, including hot pixels. Buy one today for your imaging setup! Requires Mac computer running OS X, or PC running Windows XP, Vista, 7, 8 or Windows 10 Operating Systems. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. This "guide to guiding" was created to fill that void. Guiding was PHD2 + TS Optics 9mm OAG + GPCAM1030M MOUNT : EQ6-R + Bluetooth and EQMOD IC1848 Soul Nebula - ASI1600MM Pro 200gain 22offest 224 minutes (Ha 40 x 120s Oiii 36 x 120s Sii 36 x 120s) by Nick Davis , on Flickr. The screenshot has the guiding graph and target. Unlike the old version, PHD2 will figure this out for you. PHD2 is a telescope autoguiding software that automates the process of tracking a guide star. Yo solo llevo dos días probando PHD2 pero he visto que al estar conectado a EQMOD el apartado de la declinación sale sombreado y no se puede modificar, así que entiendo que es como dices. With the Orion StarShoot AutoGuider, precision autoguiding for deep-sky photography is now easier and more economical than ever. PHD2 Guiding. A wide range of features makes SharpCap suitable for many types of astro-imaging including Planetary, Lunar, Solar, Deep Sky and EAA (Electronically Assisted Astronomy). Meade Instruments: A world leader in the manufacturing of Telescopes, Solar Telescopes, Microscopes, Optics, Binoculars, for amateur astronomers and hobbyists. Celestron's FREE planetarium app is an astronomy suite that redefines how you experience the night sky. I would feedback from those doing pointing models if would be advantageous for me to try it based on my specific setup on stick with OAG. That way I am in focus, start the sequence and the first target is centred, PHD2 starts guiding and. If you're using autoguiding software like PHD2, the default settings will usually work, but every mount-scope combination is different. 3 Coma Corrector on a Celestron Alt-Az Fork with Wedge. phd2 guider settings #27138 If you want to use PHD2 for guiding with Ekos, you can choose to have the camera connected to KStars and use it with INDI, or you can connect the guide camera directly to PHD2 if you prefer. bkp200 で oag 使った場合、実際には四隅ではなくて、ココに当たる部分を使う事になるはずで. PHD2 Guiding. Advanced settings are accessed by clicking on the 'Brain button' in the main display. This allows taking very long exposures of deep space objects. Thanks for the comments on PHD2, by the way. For me, I chose the EQMOD ASCOM HEQ5/6 profile, which then presents the following question about guide speed settings of the mount. I am using a Lakeside motorfocuser on a WO Star 71 with a QSI 683-WSG. Deconvolution: I create a luminance clone of the image and use the STF settings with Histogram Transformation to stretch it. PHD2 ran reasonable well with default settings, but ran into a couple issues. it? I compare PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given How to Setup PHD2 (Autoguide Software) I've received a lot of requests Planning and OAG Setup I go through the process of saving the ED102 imaging profile in APT before. 2015-01-01. The guide camera is focused by sliding it up or down the OAG connecting shaft of the filter wheel, and it works well. Astrodon Blue filter, 17 x 7 minutes, 1x1. I can't help you with PHD I'm afraid, but this is certainly going to be your issue. This is the exact reason I turned ‘Timed Finishing’ off in my settings. Of note, I have found the home position for the EXOS-2GT and with good PA, targets are always in frame with the first goto. PHD2 settings: RA Aggressiveness: 70, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. Total exposure time through LRGB filters is 38 hours. PHD is a free and popular application for mount guiding. Over the years we have been frustrated by a distinct lack of key features that make life easier under stars. Pixel size is 2. Unfortunately bushfire smoke looks like wiping me out for months so I haven't been able to test very much (2 nights only since last posting). So i'll try and keep this brief. The Oracle Data Integrator KMs for PeopleSoft use mature integration methods for PeopleSoft, in order to: Reverse-Engineer PeopleSoft data structures (Business Objects, tables, views, columns, keys, and foreign keys) in the form of datastores. connect the camera and mount, use PHD2 to build a dark library Setting Up An Off-Axis Guider We look at the idea behind the OAG, its challenges, and its benefits and show how Stellarium can be used to identify potential PHD2 Drift Tool Tutorial See my other 2 videos for PHD settings. 9 and it broke my QHY8 camera driver, so jumped back to a windows platform). And 16 bit cooled QHY6 also worked for me pretty well. That's an important point, well worth sharing. blireina Guest. 6 arcsec RMS. Published 24 March 2016. Needs a mount with ASCOM control. PHD2 is easy enough for a beginner to use right away, yet also includes sophisticated. Basically, SharpCap takes two pictures near the pole and analyzes them to judge the accuracy of your Polar Alignment. PHD2 Best Practices Bruce Waddington Andy Galasso Getting Started Use the new-profile wizard to specify connections Enter correct values for camera pixel size and guide scope focal length Build and use a dark library for the camera – the wizard will help you do that Use a separate profile for each gear combination Gear Connections Use ASCOM pulse-guiding instead of ST-4 guiding if mount. It can be used with dedicated astronomy cameras, webcams and USB frame grabbers. Although these are called "advanced" settings, they are not particularly difficult to understand, and you shouldn't hesitate to explore them. This "guide to guiding" was created to fill that void. x66 RGB:1min. Looping - Change in mount guide speed settings - Rotation of guide camera or OAG by more than a few degrees • Note: recalibration is still required if no ASCOM. We know they didn't come easily and that one point of these awe-striking images involves guiding a telescope for imaging. 70 Calibration Steps: 125msec Auto/Resist Switching. Using PHD2 Guiding There are five basic steps to start guiding. This camera offers 12-Bit A. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. PHD2 settings: RA Aggressiveness: 70, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. 0 - Is an Non ASCOM Focuser Control Program for "Manual" focus control of 2 focusers using a PC. Needs a mount with ASCOM control. Beginner's Guide to Setting Up Your LOSMANDY Equatorial Mount for use with PHD2 Guiding Introduction If you are reading this because you just purchased a Losmandy Equatorial mount, con-gratulations! You have one of the best mounts available today, and certainly one of the best values in astrophotography available anywhere. North Idaho Solar Activity has 477 members. ZWO OAG + 224MC. The M55 globular cluster (5x 240s and 6x 300s + darks, guided with an OAG) is taken with this new setup, with little polar alignment. I did not see any backlash. Famous low noise cooled ZWO ASI cameras. I have been struggling a little. Almost felt bad scoring on the break. Re: Colour balancing of data that was filtered by a light po by almcl » Tue Nov 08, 2016 7:51 pm Sorry it has taken so long to respond, it has taken me this long to get some decent data and even now have a monster dust bunny for which apologies. My idea it to get at least 20 hours worth of data, so expect an enhancement in the next few days. APT has been great to assist working through my efforts. An OAG sits between the focuser and the imaging camera. Captured and automated with Voyager. 晴れたり曇ったりする中球状星団なら薄雲も突き抜けてくれるかという事で撮ってみました。何度撮っても満足な感じにならないです。星の色は難しいです。200RC+CCDT67+Sx miniwheel/OAG(lodestar+PHD2)+Baader CRGB+Sx694 C:1min. 6mm, 6016x4016 3. I was pixel peeping too when I first started using guiding but always ended up messing with PHD2 settings too much and ended with bad stars even at 480mm now I image at 800mm with 10 minute exposures with perfect stars and the only thing that changed is by ignoring most of the settings in PHD2 and change only what is necessary on a night with excellent seeing and then forget it. 1, PHD2 is up to v 2. Thugocracy: U. PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration, drift alignment, reading the graph, and tweaking settings for given. Fitting Atik OAG to EFW3 and setting up for use with Lodestar X2 Atik off axis PHD Basics Part #1 Part 1 covers basic settings on PHD2 Part 2 covers calibration,. Nikon D5300. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. I use the output reference masks to make sure the settings are correct. Click the "Calculate" button, enter your guide scope focal length (or main scope focal length if you are using an OAG), pixel size, and mount guide speed, and the program will give you a value in milliseconds to enter in the calibration step field. In this study, we investigated the potential molecular mechanisms. 5/4 x 6 x12 footers x 27 **for the decking. Although these are called "advanced" settings, they are not particularly difficult to understand, and you shouldn't hesitate to explore them. PHD2 Best Practices Bruce Waddington Andy Galasso Getting Started Use the new-profile wizard to specify connections Enter correct values for camera pixel size and guide scope focal length Build and use a dark library for the camera – the wizard will help you do that Use a separate profile for each gear combination Gear Connections Use ASCOM pulse-guiding instead of ST-4 guiding if mount. zipがリリースされているので、MacBook Pro. I have frequent problems with the camera failing to deliver images to PHD2 (Eg, looping mode hangs, giving a camera timeout error) (eg making a dark frame library in PHD2 gets started but often fails before ge. Open this and check the 'Activate stretch display' check box. Smiling Face. With OAG I have successfuly used QHY5 and ASI120, but more sensitive ASI290MM gives more stars. As its name indicates, off axis guider. There is debate here, once i have it up with the dome, i might consider laying plywood ontop of the 5/4 to seal off from critters and then use the interlocking foam mats everyone uses for flooring, along with rubber padding along the edges of the dome, as well as caulking on the outside of the dome (the 27th is a spare). I wonder if I am using SGP correctly to autofocus… It works, but it can take quite a while and has occasionally failed me. A wide range of features makes SharpCap suitable for many types of astro-imaging including Planetary, Lunar, Solar, Deep Sky and EAA (Electronically Assisted Astronomy). PHD2 ran reasonable well with default settings, but ran into a couple issues. PHD2 settings: RA Aggressiveness: 60, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. It consists of 18 x 20mins subs. In a subsequent video, I will show you how an off-axis guider will improve PHD2 guiding. Hello everybody, I'm taking the step and going OAG. The Low limit for the white was set just above the noise level and the High limit for the Shadows was set just above this noise level as well ~0. Fed-Police Vigilantes Persecute Citizen Targets * ETK Introduction: This series of articles and posts, compiled between 2010 and 2012 by Geeldon, may be the single most informative and important post on this website. Calibration and Post-processed with PixInsight. I am pretty new using PI, but reaching out for a little help to see if this can be resolved in processing. 5 Tips for Better PHD2 Guiding. To view the blog post by NIDA Director Dr. Canon's EOS Rebel SL3 / EOS 250D is the latest in the company's line of diminutive DSLRs. You get a Aug 12, 2017 · BEST Video Settings To Record Video On ANY Nikon DSLR (D5200/D5300/D5500 FULL Tutorial) - Duration: 16:05. 0 Megapixel IMX178 STARVIS Exmor R back-illuminated CMOS sensor. Starlight Xpress Lodestar Autoguider Starlightxpress Lodestar Autoguider Lodestar Autoguider - Starlight Xpress Ltd The Starlight Xpress Lodestar X2 Autoguider is a popular guide camera for deep-sky astrophotography In fact, the original Lodestar was considered to be the best autoguider on the market for a long time The X2 version is the successor to the original Starlight Xpress Lodestar. Famous low noise cooled ZWO ASI cameras. The ability to 'bin' the CCD means the QSI-6162 is suitable for focal lengths right up to 2. This is very useful in OAG to looking for a guide star. The image from the guide camera is then analysed by a piece of software called PHD2. Je kan met PHD de volgende settings doen: Mount = On-camera, Aux Mount = none In deze instelling stuurt PHD2 guide commando's naar de camera en de camera stuurt deze door naar je mount. Galaxies NGC3628, M66 and M65 in the constellation Leo(Leo Triplet). SharpCap Settings: Capture Area=800x600 Binning=1 Colour Space=RGB24 Gain=217 Exposure=0,057716 White Bal (B)=99 White Bal (R)=57. An OAG sits between the focuser and the imaging camera. For now, it appears that the Starlight Xpress SXV-AO-LF together with PHD2 is the only solution to address the differential-flexure issue with a second imaging camera. The deep-sky images look so exquisite with their masses of detail and perfectly round, pinpoint stars. This "guide to guiding" was created to fill that void. I can't help you with PHD I'm afraid, but this is certainly going to be your issue. Product SKU: 52064. For me, I chose the EQMOD ASCOM HEQ5/6 profile, which then presents the following question about guide speed settings of the mount. Maybe also play with the spacing to my camera. big SCTs) to avoid flexure issues. Die Idee, dass man die Guiding-Kamera (am OAG) ausgerichtet auf die Achsen montiert, wäre die, dass so das Pol-Align in PHD2 auch ohne vorherige Kalibrierung funktioniert. In this For example, you can guide using PhD2 and focus through ASCOM. PHD is a free and popular application for mount guiding. 404 membros. PHD2 Best Practices Bruce Waddington Andy Galasso Getting Started Use the new-profile wizard to specify connections Enter correct values for camera pixel size and guide scope focal length Build and use a dark library for the camera – the wizard will help you do that Use a separate profile for each gear combination Gear Connections Use ASCOM pulse-guiding instead of ST-4 guiding if mount. Open this and check the ‘Activate stretch display’ check box. Getting Started for the PHD2 'aux mount' connection. There is some backlash in both the RA and Dec axes. PHD2 settings: RA Aggressiveness: 60, RA Hysteresis: 10, Max RA/Dec Duration: 2000, Min Move: 0. 2015-01-01. I'm always fighting, without success, with my guiding settings in PHD2. So i'll try and keep this brief. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. with the focal. PHD2 options For PHD2 you need to set the network name of the computer running PHD2 and the port number. My idea it to get at least 20 hours worth of data, so expect an enhancement in the next few days. Off-Axis Guider - User's manual Thank you for purchasing the Atik Off-Axis Guider (OAG). Tja und da beißt es sich halt. Calibration and Post-processed with PixInsight. the entire night UPDATE: My PHD2 settings for the focal length of my guide scope were wrong - so my guiding results aren't as good as PHD2 was indicating. First, it warned me I should disable Synchronous Pulseguide in the driver, I couldn't find that setting and not sure I want to disable even if I could!. Emily Einstein Discusses How Overdose Deaths are Counted. I have been using PHD2 for a few months on a refractor. But I'm frustrated by the polar alignment. Had to throw out one sub due to really bright airplane light streaks. After a couple of nights, finally I got most of the settings right. Don't worry, I'm not going to dig in to how the light moves through the prism etc. Fitting Atik OAG to EFW3 and setting up for use with Lodestar X2 Atik off axis (+ PHD2 Guiding) Astro Photography Tool and tweaking settings for given Celestron C9. I wonder if I am using SGP correctly to autofocus… It works, but it can take quite a while and has occasionally failed me. Calibration (including Dark Subtraction) and Post-processed with PixInsight. Replied by Daan on topic Connect ZWO Asiair to Avalon Linear (Stargo) problem is solved In the telescope settings there is a pulldown menu in which you can select next to the "Avalon Stargo" mount also the mount "Avalon Legacy". OAG and Ultrastar autoguider, Optec Handy Stepper Motor focuser. 2″ big sensor which means you can have a 4 times bigger Fov than 120mm. The OAG uses a male C-mount and I ended up getting this c-mount to t-thread adapter from ScopeStuff and the Baader helical focuser from Adorama. l have had some success with PHD2 using the asi290mm and oag. Now that M31 is again well placed in the sky it gave me the perfect opportunity to test out a focal reducer on my Takahashi FSQ85 which frames this beautiful galaxy nicely. FocusLock Software Quick Start Guide Thank you for purchasing FocusLock, the most advanced auto-focus software available for off-axis guiders and the ONAG On-Axis Guider developed by Innovations Foresight. Make sure that the OAG is pushed in as the stars in the outer areas might be too dim; One user has the exact same setup that I have - except that he does not use a focal reducer. bkp200 で oag 使った場合、実際には四隅ではなくて、ココに当たる部分を使う事になるはずで. Color or Mono CMOS sensors to be cooled to 35C to 40C degrees below ambient! more. 70 Calibration Steps: 125msec Auto/Resist Switching. Driver support: PHD2, AltairCapture, SharpCapAltairCapture OS support: Win XP 32bit / Vista / 7/8/10 (32 & 64 bit) NOTE: Windows 10 is recommended for best USB performance, with 2013 or later USB host controller v1.